Battery Module
LFPA
LFP
Model | V | Ah | W(mm) | L(mm) | H(mm) | kg |
LFPA-10 | 3.2 | 10 | 19 | 65 | 140 | 0.34 |
LFP-20 | 3.2 | 20 | 116 | 46 | 183 | 1.3 |
LFP-30B | 30 | 116 | 46 | 183 | 1.4 | |
LFP-30A | 30 | 115 | 36 | 200 | 1.4 | |
LFP-40 | 40 | 115 | 36 | 200 | 1.5 | |
LFP-50 | 50 | 115 | 36 | 200 | 1.6 | |
LFP-60 | 60 | 116 | 61 | 184 | 2 | |
LFP-70 | 70 | 143 | 61 | 218 | 3.1 | |
LFP-80 | 80 | 115 | 72 | 200 | 3.3 | |
LFP-90 | 90 | 142 | 61 | 221 | 3.1 | |
LFP-100 | 100 | 142 | 61 | 221 | 3.2 | |
LFP-160 | 160 | 180 | 70 | 280 | 5.7 | |
LFP-180 | 180 | 180 | 70 | 280 | 5.7 | |
LFP-200 | 200 | 180 | 70 | 280 | 5.8 | |
LFP-300 | 300 | 360 | 53 | 309 | 9.5 | |
LFP-400 | 400 | 450 | 71 | 285 | 14.3 |
UPS / CHARGER
Features
• Stable AC power supply applies a high frequency power conversion circuits
• Enter Sruge, Sag, Outage, Spike, Dup, including protection from various types of commercial power failure
• Based on the microprocessor to provide ease of application Digital Display Operation
• Excellent transient characteristics (0↔100% during the rapidly changing ± 4%, within 20ms response time)
• Checking the status display provides easy operation
• Various state and alarm display features
• Computing equipment, communication equipment, medical equipment, testing equipment, control equipment,
etc. designed for small and medium load capacity equipment that requires a High Quality Power
Technical Data
Division | Characteristic | ||
Volume | 15~20kVA | 25~100kVA | |
Control Method | Rectifier / charger | SCR Full bridge phase control method | |
The inverter section | High frequency PWM control scheme | ||
Static S / W switching scheme | Fushun synchronous switching stage | ||
Input | Voltage | 3Ø 3W/4W 380/220V ± 10% | |
Frequency | 50Hz or 60Hz ± 5% | ||
Output | Voltage | 1Ø 2W 220V | |
Frequency | 50Hz or 60Hz ± 0.5% | ||
Voltage Stability | Within ± 2% | ||
Transient Voltage fluctuations | ± 4% (when changing 0↔100%) | ||
Transient response time | Within 20ms | ||
Distortion | Less than 3% (linear load) | ||
Overload capacity | 125%, 10 seconds | ||
Synchronous Transfer Switch | Transfer time | Within 4ms | |
Transfer conditions | Inverter Fault, Overload, low voltage direct current, for manual switching | ||
Battery | Category | Sealed maintenance-free | |
Voltage | 216V(12V x 18 Cells) | 240V(12V x 20 Cells) | |
Cooling system | Wind force cooled | ||
Remote Monitoring | RS-232, RS-485 communication ports / SNMP Optional | ||
Temperature conditions | 0 – 40ºC | ||
Humidity | Below 90% | ||
Dimension | 10~20kVA | 700 x 800 x 1500 | |
(W x D x H, mm) | 25~30kVA | 800 x 800 x 1830 | |
40~50kVA | 1330 x 800 x 1830 | ||
60~100kVA | 1630 x 800 x 1830 |